Guideline 4000 LP+™
Catalog Number: MT-LPP
As the newest member of the Guideline 4000™ family, the microTargeting™ Guideline 4000 LP+™ Neuromodulation Targeting System features the power of the Guideline 4000™ in a light, portable package.
The microTargeting™ Guideline 4000 LP+™ offers neurosurgical teams the power of the Guideline neuromodulation targeting family in a compact, streamlined package. The entire LP+ system fits into a single padded, lockable shipping case, making transport simple and convenient. Alternatively, the LP+ system can be permanently installed on an ergonomic cart with a locking cabinet and adjustable tabletop height. Modular by design, the LP+ can be configured to meet the specific needs of the customer, including user-specifiable channel count and optional drive accessories. The LP+ places a priority on meeting the clinical requirements of a targeting system, offering one-click recall of user preferences, side-by-side review of all recorded snapshots, and fully integrated stimulation and impedance check capabilities. Still, with independently-adjustable filter settings, ultra-wideband recording capabilities, and dedicated earth-referenced analog outputs for all channels, the LP+ can support the highest-powered research endeavors. Further, by providing seamless data export to MATLAB and NeuroExplorer, the LP+ enables users to create and run customized data analysis scripts, online or offline. Featuring simplified software and streamlined hardware, the LP+ is the latest generation of Guideline power, with an even stronger emphasis on reliability and usability.
• One to five recording channels supported, according to user preferences. Includes:
• Two auxiliary analog inputs.
• One auxiliary digital input.
• Independent, earth-referenced analog outputs for all recording channels.
• Standard 3.5 mm stereo jack for earth-referenced audio output.
• Micro- and macro-stimulation and impedance check supported on all channels.
• Independently adjustable digital filters on all channels.
• Powerful PC laptop and high-quality, self-powered desktop speakers included.
• Optional kit (MT-LPP-MEPK) includes USB-powered neuro/craft™ QuickWave handheld function generator and model electrode for equipment testing and analysis.
• Supports one microTargeting™ STar™ Drive motor/encoder system.
• Stimulation remote control included for ease of use.
• Optional “breakout box” (MT-LPP-BOX) to independently feed out channels to downstream recording/analysis systems.
• Independently adjustable sampling rate, adaptive line noise filter, and gain for each channel.
Physical Specifications
Dimensions:
Height: 5.5” (14 cm)
Width: 17” (43.2 cm)
Depth: 15.25” (38.7 cm)
Weight: 16.85 lbs (7.6 kg; enclosure only)
Power Requirements
100-240 VAC, 50/60 Hz, 2A
Microelectrode Recording Channels
Analog signal conditioning
Cable: 66-EL-LP or equivalent only.
Inputs: Differential or single ended Software configurable
AC/DC coupled, factory configurable
Input Impedance:
1013Ω ║ 0.2pF AC, 200MΩ DC Differential
1013Ω ║ 7.0pF AC, 200MΩ DC Common Mode
Gain:
Preamp: 54 X
Amplifier: 0.25X to 665X user adjustable
MER Preamp Configuration:
Upper frequency cutoff: 20kHz, 40dB/decade roll-off
Lower frequency cutoff 125Hz, 20dB/decade roll-off
Ultra-wide Preamp configuration:
Upper frequency cutoff: 20kHz, 40dB/decade roll-off
Lower frequency cutoff 0.2Hz, 20dB/decade roll-off
Auxiliary Input/Output
Auxiliary Input/Output Isolation from the patient circuit: (note: auxiliary IO jacks are earth referenced and not isolated from one another)
Dielectric Strength: >=4000VAC
Creepage Distance: >=4mm
Clearance Distance: >=2.5mm
Analog Inputs:
Quantity: two
Input Characteristics:
Coupling: factory configurable AC or DC coupled
Range: factory configurable from among following: (0-16V), (-8.0V to +8.0V), (0 to 4.0V), (-2.0V to +2.0V), (0 to 1.6V), (-800mV to +800mV), (0 to 400mV), (-200mV to +200mV), (0 to 160mV) and (-80mV to +80mV)
Bandwidth: 0 to 5.0kHz
Earth referenced, non-isolated
Analog Outputs:
Quantity: Five
Range: factory configurable: unipolar (0 to 3.0V) or bipolar (-1.5V to 1.5V) if bipolar, the output may also be AC or DC coupled
Earth referenced, non-isolated
Propagation delay: 580 µsec, filters off
Digital Inputs:
Quantity: One
Input Characteristics: TTL compatible, 1KOhm pull-down internal
VIH: 2V min
VIL: 0.8V max
VI: 0 to 5V (20mA max input current)
Earth referenced, non-isolated
Stimulation
Implementation: isolated, constant current stimulator with different ranges for microstimulation, macrostimulation and impedance checking. Stimulus waveforms are automatically routed to the appropriate contact as follows:
Macrostimulation
Cathode: macro-contact of selected cathode electrode
Anode: macro-contact of anode electrode or patient common according to anode selection
Microstimulation and Impedance Check
Cathode: microelectrode contact of selected cathode electrode
Anode: patient common
Stimulus Current Amplitude:
Compliance Voltage: ±60V
Macrostimulation
Range: 0 to 10.0 mAp-p
Display Resolution: 10 µA
Accuracy: ±5%
Adjustments: continuous adjustment using remote control amplitude knob. Resolution of 0.1mA every 7.2° degrees.
Microstimulation
Range: 0 to 100µAp-p
Display Resolution: 1 µA
Accuracy: ±5%
Adjustments: continuous adjustment using remote control amplitude knob. Resolution of 1µA every 7.2° degrees.
Stimulus Waveform:
Pulse Train Polarity: user selectable from following options
Bipolar positive going leading pulse (default)
Bipolar negative going leading pulse
Unipolar positive pulse
Unipolar negative pulse
Pulse Train Frequency: 10Hz, 20Hz, 30Hz, 50Hz, 75Hz, 100Hz, 125Hz, 150Hz, 175Hz, 200Hz, 250Hz, 300Hz. Pulse Duration: 50, 75, 100, 150, 200, 300, 500, 1000µs note that for bipolar pulses, the duration includes both phases of the pulse.
Stimulus Duration:
Manual: stimulus while user holds down the stimulate button on the remote control
Timed: user selectable from among the following options: 0.5 sec, 1 sec, 2 sec, 3 sec, 5 sec, 10 sec, 20 sec, 30 sec, 60 sec
Impedance Check
Implementation: impedance measured from microelectrode to patient common, software or hardware triggered, single channel at a time, multiple channels can be measured sequentially. Impedance result is displayed on notebook display and result is stored as an event.
Measurement Stimulus
Waveform: sine wave
Frequency Range: 100Hz ±5% to 5kHz ±5%. 1kHz default
Amplitude: 1.0µA RMS
Duration: 1.0 to 10.0 sec. adjustable
Measurement Result
Range: auto-ranging 10M, 1M, 100k
Accuracy: ±10% of full range
Resolution: 2 digits
Remote Monitoring: Yes
Data Server: All spike sweeps (discriminated or not) and all chart recorder data as well as time stamps from digital inputs
Notebook Computer
Model: Dell Precision M6400
Processor: Intel® Core™2 Duo P8600, 2.40 GHz, 1067 MHz
Memory: 4.0 GB DDR3-1055 SDRAM
Video Card: 512 MB NVIDIA Quadro FX 2700M
Hard Drive: 80 GB Hard Drive 9.5 MM, 7200 RPMFFS
Display: 17 inch (43 cm) WXGA+ LCD screen
Speakers:
Model: Bose Computer MusicMonitor
Power: 100-240 V, 50-60 Hz AC
Driver: magnetically shielded, full range driver
- Guideline 4000 LP+™ Mobile Electrophysiologist Kit
- microTargeting™ Controller
- Guideline 4000 LP+™ Cart
- Guideline 4000 LP+™ Extra Channel
- Guideline 4000 LP+™ Breakout Box
- Guideline 4000 LP+™ Double Soft Transport Cases
- Guideline 4000 LP+™ Single Hard Transport Case
- Position Display Assembly
- microTargeting™ Handheld Remote Control
- Power Assist with Display Assembly
- Accelerometer Adapter Unit (AAU)
- Accelerometer on Wrist Band
- Onsite Case Support, Including Equipment
- Guideline 4000 LP+™ One Year Service Agreement
- Wireless Headphones
- Onsite Equipment Operation
- Guideline 4000 LP+™ Installation
- Guideline 4000 LP+™ Electrode Cable
- Guideline 4000™ Software Version 1.50
- Guideline 4000 LP+™ Line Cord (USA)
- Guideline 4000 LP+™ USB to Serial Converter Package for microTargeting™ Controller
- Guideline 4000 LP+™ Training
- QuickWave Function Generator